Oregon UHF Talkgroup Matrix
for Managers, TG Appearances & Timers
VHF repeaters: VHF page  //  OR-SAR repeaters: OR-SAR page
 

This is the controlling document used by PNW DMR for tracking its repeater managers, talkgroups and their timers

Talkgroup/
TG Viewer

TG ID

TS

Salem
Newberg
Gresham
Hospital
Portland
Mount Scott
Portland
PPMC
 
Talkgroup/
TG Viewer
Audio Test 2 9999 2 P2/0 P2/0 P2/0 P2/0 Audio Test 2
Bridge 2 (bm) 3100 2 P15/m Current for now   Bridge 2 (bm)
British Columbia 1 3027 1 P15/m but likely to change   British Columbia 1
Comm 1 3777215 1 P15/m in the weeks ahead   Comm 1
DCI 1 3160 1 P15/m       DCI 1
DCI 2 3162 2 P15/m       DCI 2
I-5 3168 1 F/m F/3m F/3m   I-5
I-84 31419 2   F/3m F/3m   I-84
Local 1 3181 1 F/5 F/5 F/5 F/5 Local 1
Local 2 3166 2 F/5 F/5 F/5 F/5 Local 2
Mountain 2 (bm) 3177 2 P15/m       Mountain 2 (bm)
Net 2 31002 1   Nets Only PTT Nets Only PTT   Net 2
North America 2 3163 2 P5/m       North America 2
Oregon 1 (bm*) 3141 1 F/m F/3m F/3m F/3m Oregon 1 (bm)
Parrot 1 9998 1 P2/0 P2/0 P2/0 P2/0 Parrot 1
PNW 1 3187 1 F/m F/3m F/3m F/3m PNW 1
PNW 2 103187 2 F/m F/3m F/3m F/3m PNW 2
PNW Regional 2 31771 2   P15/m P15/m P15/m PNW Regional 2
SoCal 2 31066 2   P15/m P15/m   SoCal 2
SNARS 2 31328 2 P15/m       SNARS 2
TAC 1 8951 2   P15/3m P15/3m P15/3m TAC 1
TAC 310 (bm) 310 2 P15/m       TAC 310 (bm)
USA 2 1776 2 P15/m       USA 2
Washington Statewide 1 3153 1 P15/m     P15/3m WA 1
Washington 2 103153 2 P15/m     P15/3m WA 2
Worldwide 2 3161 2 P10/m       Worldwide 2
Worldwide English 2 13 2 P10/m       Worldwide English 2

Talkgroup

TG ID

TS

Salem
Newberg
Gresham
Hospital
Portland
Mount Scott
Portland
PPMC
Talkgroup

Data / Private Call

    N/No N/No N/No N/No Data/Private Call

MCT Enabled

    Yes Yes Yes Yes MCT Enabled
 
How to use the matrix:  Find the repeater column and then scan down to see which talkgroups are listed.  Or to find where a talkgroup may appear, locate the talkgroup of interest and scan across for repeaters that carry that talkgroup.  The entry at the intersection tells you if it is carried full-time (F) or if it is on PTT (P).  If a "P" then the numbers indicate how long the talkgroup is active after any local kerchunk or key-up is initiated.  The number after the forward slash (/) indicates how long it will hold off most other talkgroups on that timeslot after the last local kerchunk.  These timers and MCT's help to insure that an active local talker will not lose that talkgroup.

All PTT actions connect a TG immediately if their is no active talker.  HOWEVER: if there is an active talker, at the time of your PTT or Kerchunk, the talkgroup traffic will not be connected or heard by you until the current talker unkeys and the next talker keys-up.

Master Control Talkgroups or MCT's may be implemented to provide more control over the timeslot than the timer based "hold off's".  New managers are now being programmed for active local repeater users' control and relying on Hold-off timers far less but some HO's may be coded as a convenience to users, possibly: BC 1, DCI 1, I-5, ID 1, PNW 1 OR 1, WA 1

Typical PTT talkgroups have an "on-timer" for 15 minutes and most have "hold-off timers" for 3 minutes.  Not all hold-off timers for the PTT TG's may be in place.  Some TG's have a bare minimum as indicated by "P15/0" as they are quick to program and somewhat useable for PTT purposes by repeaters that have not expressly requested those particular talkgroups.  In other words, the talkgroup is programmed into the manager and usable via PTT but the more involved programming to implement the hundreds of hold-off timers, has not been implemented.  So it is probable that other talkgroups may capture the slot and stomp on these "zero" talkgroups, especially the full time talkgroups.  Somewhat of an approach that "it is better than nothing".

Columns:  F/y = Fulltime / Hold-off Timer (y min or mct)
Columns:  Px/y = PTT On Timer (x min) / Hold-off Timer (y min)
Columns:  Pr/y = PTT On Timer (x min) r = Receive Only / Hold-off Timer (y min)
Columns:  Px/0.f = HO's only for the fulltime TG's for minimal control (.f = fulltime)
 

Blank = No appearance of TG on manager
+ = Some hold-off timers are in place but incomplete
programming
MCT controls = 55 or 59 min On / 15 or 29 min Off and may or may not have supplemental HO's for fulltime talkgroups for better experience

This slate of talkgroups has been approved by each repeater owner or manger admin.  If you want changes, additions or deletions, then the owner or admin must agree to that.  Please contact them directly for discussion of any changes.

Local 1 and Local 2 are not connected outside of its manager/IPSC network unless by special request.  Hold-off timers may turn off some networked talkgroups for 5 minutes as a loose form of priority to locally generated traffic.  Some custom managers may hold-off talkgroups for up to 2 hours for Search and Rescue, EMCOMM or other public service events.

This matrix is now the baseline or controlling document to determine all interactions on each manager.  If you have any issues with talkgroups, stomping on other talkgroups, etc, please look to this chart, determine what should be the listed action and then armed with that information, report issues.

 Questions about your manager     /     Return to PNW's Home page

 Revised: 08/14/2019 16:31

 

Contact PNW

Webmaster